Daily Maintenance and Common Faults of High-Temperature Discharge Units
A complete high-temperature discharge unit comprises a motor, a reducer, a coupling, and a housing. The head assembly consists of the housing, front and rear side covers, the main shaft, sliding bearings, and a shaft seal. The high-temperature discharge unit is a positive-displacement type; during operation, it conveys molten material by means of the volume change created through the meshing of the driving and driven gears.
A complete high-temperature discharge unit comprises a motor, a reducer, a coupling, and a housing. The head section consists of the housing, front and rear side covers, the main shaft, sliding bearings, and shaft seals. The high-temperature discharge unit is a positive-displacement type; during operation, it conveys molten material by means of the volume changes created through the meshing of the driving and driven gears. The working chamber is formed by the housing, the grooves of the groove wheels, and the bearings that also serve as side plates. As the gears rotate, the molten material enters the tooth spaces between the two gears in the suction chamber; with further rotation, the material is carried from both sides into the discharge chamber. When the gears re-mesh, the molten material in the tooth spaces is forced out into the discharge chamber and then conveyed to the outlet pipeline. As long as the pump shaft rotates, the gears continuously press the molten material toward the outlet, enabling the outlet pressure to reach very high levels, while the flow rate remains essentially independent of the discharge pressure.
I. Operation and Management of High-Temperature Discharge Units
1. Daily Maintenance
(l) The disassembly and cleaning of the high-temperature discharge device, as well as its heating and cooling procedures and start-up and shutdown operations, must be carried out strictly in accordance with the relevant regulations to prevent unnecessary losses.
(2) It is important to maintain stable pressure in the pressurized air supply system to ensure consistent volumetric efficiency, thereby promoting stable operation of the system and consistent downstream spinning quality.
(3) For packed shaft-seal pumps operating under negative pressure, the pressure in the packing gland must be maintained above atmospheric pressure. When the backpressure drops, the packing-gland pressure should be adjusted promptly; otherwise, air may be drawn into the pump, leading to breakage of the extruded filament, impaired pelletizing, and subsequent discharge from the pelletizer.
(4) The temperature of the heating-medium jacket shall be monitored regularly, and the heating-medium temperatures of the main body and the front and rear covers must be kept consistent.
(5) Each time the production output increases, record the corresponding output, rotational speed, outlet and inlet pressures, and current values, and compare the data before and after the change. Conduct a thorough analysis to promptly identify any abnormalities and take timely corrective action.
2. Common faults and countermeasures for high-temperature discharge devices are as follows:
(1) Fault phenomenon: inability to discharge material. Fault causes: a) Rotational direction is reversed; b) Suction or discharge valve is closed; c) No material at the inlet or inlet pressure is too low; d) Viscosity is too high, preventing the pump from engaging the material. Countermeasures: a) Verify the rotational direction; b) Check whether the valves are closed; c) Inspect the valves and pressure gauges; d) Measure the liquid viscosity and verify, when operating at low speed, whether the flow rate corresponds to the speed ratio. If flow is observed, it indicates insufficient inflow.
(2) Fault phenomenon: Insufficient flow rate. Fault causes: a) Suction or discharge valve is closed; b) Inlet pressure is low; c) Discharge pipeline is blocked; d) Stuffing box leakage; e) Rotational speed is too low. Countermeasures: a) Verify whether the valve is closed; b) Check whether the valve is open; c) Confirm that the discharge rate is normal; d) Tighten the packing; if there is significant leakage that affects production, stop the pump, disassemble it for inspection; e) Check the actual rotational speed of the pump shaft.
(3) Fault symptoms: Abnormal noise. Fault causes: a) Excessive coupling misalignment or inadequate lubrication; b) Motor failure; c) Reducer malfunction; d) Improper installation of the shaft seal; e) Shaft deformation or wear. Countermeasures: a) Perform alignment adjustment or replenish grease; b) Inspect the motor; c) Inspect bearings and gears; d) Inspect the shaft seal; e) Shut down the equipment and perform a thorough disassembly inspection.
(4) Fault phenomenon: Overcurrent. Fault causes: a) Excessive outlet pressure; b) Excessive melt viscosity; c) Improper packing of the shaft seal; d) Wear of the shaft or bearings; e) Motor failure. Countermeasures: a) Inspect downstream equipment and piping; b) Test the viscosity; c) Inspect the shaft seal and make appropriate adjustments; d) After shutdown, check by manually turning the shaft to see if it is excessively heavy; e) Inspect the motor.
(5) Fault symptoms: sudden shutdown. Causes: a) power outage; b) motor overload protection; c) coupling damage; d) excessively high outlet pressure triggering interlock protection; e) abnormal jamming inside the pump; f) shaft and bearing seizing due to adhesion. Countermeasures: a) check the power supply; b) inspect the motor; c) remove the guard and manually turn the rotor for inspection; d) verify the instrument-based interlock system; e) after shutdown, perform forward-and-reverse manual turning to confirm operation; f) manual turning confirmation. Note: the above fault symptoms and corresponding countermeasures are in a one-to-one correspondence. II. Measures to Extend the Service Life of High-Temperature Discharge Units Since the equipment operates at high temperatures, hinged supports should be installed on the piping during cold-state installation to prevent pipe displacement as the temperature rises.